This is what we are heading for and we ask your comment and very specially your knowledge about prior experience with a similar setup:
This experiment is described at 1, 2, 3.
Findings
Re. 1: Only the exhaust was led to an opening in the wall. Air was sucked in underneath the stove. The idea of preheating could not be checked, as the tiles used to line the firebox cracked immediately when heated. The tiles were shielded off with thin stainless steel sheet metal. Being occupied with moving Demotech from Dieren to Maastricht at that time Hans Baarslag and I did not give a follow-up to the first testing.
Re 2: We used an electric ventilator from a kitchen unit. Its capacity could be regulated with a dimmer. There was no danger for burning the plastic ventilator rotor, as temperature at that spot was no more than luke warm. The stove was build in haste and had plenty leaks. So the ventilator has to suck hard to force enough air through the fire box. The hot air from the fire box first passed through a stone channel, then moved outside the bricks, but inside metal sheets. For this reason the brick stove started producing heat immediately after firing. Because the brick walls in the stove retained part of the heat, the stove remained warm long after the fire in it extinguished.